Construction and storage of anti-corrosion steel

Construction and storage of anti-corrosion steel:

(1) Before painting iron surface treatment Sa2.5 stage, construction is strictly prohibited into the water, dust, oil and brushing in order to ensure quality.

(2) Coating ratio: Group A points (base), Part B (hardener) = 9kg paint: 1kg hardener (or press I plant told proportion ratio of construction).

(3) Construction ratio methods are: Group A points big mouth open, will join Group A Group B points since the beginning, stir evenly. Aging for 30 minutes, it can be coated.

(4) This material requirements with the distribution with the use of paint after the ratio shall be used within six hours. Not finished with the material to be sealed.

(5) Rainy days or greater than 75% relative humidity should stop construction. For severe corrosive media site, the proposed multi-channel brushing.

(6) The product should be stored in a cool dry place to prevent direct sunlight, separated from fire, away from heat.

(7) Storage period of twelve months after the expiry of the technical indicators should be examined, such as the specification requirements, you can continue to use.


Post time: Nov-16-2020